Open this FSSB menu from screen soft key ( first HRV3 means FANUC screen, SV(A1 L/M/N) means Combi drive, SV(A2 L/M) means power module, SDU (M1) means scale )
Here RED mark in SV (A2 L/M) means this module not get 24Volt. ( Here we remove control card from power module this inside 3.2Amp fuse blown )

Below message SYS ALARM 129ABNORMAL POWER SUPPLY (AMP 03)/LINE1

Below message SYS ALARM 130 ABNORMAL POWER SUPPLY (SDU01)/LINE 1

Description: An abnormal condition was detected in the power for the unit .
Countermeasures: A Voltage drop was detected in the power supplied to the unit of interest. check to see if there is any abnormality in the power supply or power supply cable and if there is voltage drop in the input power due to surge current.
Check SMPS 24 voltage measure

FANUC screen backside 24 volt DC measure

24 volt DC power module( COMBI DRIVE ) measure

Also check below parameter 1902 bit1 ( high or low)

24000 to 24007 parameter


987 parameter check

Double motor module inside fuse 3.2Amp ( on control card circuit) if 3.2Amp fuse failure, So above alarm arrive on screen, FSSB communication error alarm arrive.